Thanks to Mectronic's Real Time Switching technology, Doctor Tecar Therapy devices are able to emit distinct frequencies.
Doctor Tecar Plus has 7 of them, with the widest range among devices on the market:
300 kHz, 448 kHz, 500 kHz, 750 kHz, 1 MHz, 1.2 MHz and 1.5 MHz.
These enable better and more precise treatment of different tissues at different depths and, consequently,
surface and deep pathologies. In addition, the 448 kHz frequency is the subject of numerous scientific studies.
Doctor Tecar Plus makes it possible to carry out a frequency swing, i.e. to define the initial frequency, the final frequency and the time interval in which to maintain a given frequency.
Thanks to the wide range of frequencies, exclusive to this Mectronic device, the Swing makes it possible to act on different tissues or close tissues in the same treatment, making Doctor Tecar Therapy an even more performing and effective therapy.
Doctor Tecar Plus is equipped with an innovative system that measures the amount of energy transferred to the tissues in the treated anatomical area in relation to time and power supplied. This amount of energy is shown to the therapist on the display and communicated with an acoustic signal. The Biotransfer trace system makes it possible to assess active hyperemia and the resulting increase in electrolyte flow, as it shows the change in electrical impedance during treatment compared to the initial value at rest. This variation lasts until after the end of treatment, guaranteeing correct and continuous oxygenation of all treated tissue components. Furthermore, with the Biotransfer trace system it is possible to measure the variation of biotransfer during treatment.
at the service of therapists and patients
Thanks to the 10.1" touchscreen display, the MecOS 5.0 system guides the operator in the management of therapy in a simple and intuitive way, guaranteeing excellent results from the very first use.
Doctor Tecar Plus also includes the innovative SSDTS (Soft Start Doctor Tecar System), which gradually releases energy only after contact has been made.
The SSDTS system makes therapy extremely effective, safe and controlled, avoiding the risk of annoying shocks.
Doctor Tecar Plus has an interactive menu with a Library of over 90 therapy protocols for treating the most common problems, specially designed and divided according to the anatomical area to be treated. These protocols are also available for the automatic AVx mode, as each pathology can be treated in both manual and automatic modes.
The software also offers the security of immediate visual control, as the side panel that appears during therapy shows power, frequency, emission mode, therapy time, plate position and treatment area and, in automatic AVx mode, also the position of the electrodes.
Joule mode allows the therapist to set the specific amount of energy required for treatment. When the set value is reached, therapy stops automatically.
With the Joule/cm² mode, the dosage (10 J/cm2) can be entered first and then the anatomical area to be treated is selected.
Rounded applicators
Flat applicators
SOFTWARE
|
Mectronic’s own MecOS 5.0 Real-Time Operating System |
POWER
|
200 VA effective (600 Wpp) |
BIOTRANSFER
|
Display and acoustic with dynamic detection |
COUPLING
|
Contact control system |
CABLE CHECK
|
Guided procedure with graphic and acoustic feedback |
DISPLAY
|
10.1” HD IPS color display with capacitive touch screen |
FREQUENCIES
|
7 frequencies: |
PROTOCOLS
|
• Over 150 preset protocols |
EMISSION
MODE |
• CW • Adjustable Pulsed • Dimmer |
OPERATION
MODE |
• Resisitive • Capacitive • Custom • Swing |
WORK
MODE |
• Timer • Joule • Joule/cm² |
SPECIAL
MODES |
Protocols to maximize the main effects: |
AVX AUTOMATIC
MODE (optional) |
• Simultaneous automatic mode |
POWER SUPPLY
|
100÷240 V 50÷60 Hz |
ABSORPTION
|
350 VA |
DIMENSIONS
|
• Device: 295 x 265 x 150 mm |
WEIGHT
|
• Device: 4,5 Kg |
COMPLIANCE
|
IEC/EC 60601-1, 60601-1-2 |
CERTIFICATION
|
CE0051 |
DIRECTIVE
93 / 42 / CE |
Classification llb |
WARRANTY
|
2 Years |
Mectronic's Doctor Tecar therapeutic devices have been the subject of various scientific studies:
“ Surgeon and Physiotherapist”
Set yourself apart from the competition, invest in the
well-being of your patients
How many patients come to you every week?
How many of them could you treat effectively with Doctor Tecar Plus?