We have integrated five technologies to create an advanced and unique device: dry, cold and hot air, THEAL laser therapy, thermal shock and THEAL-CRIO synergy.
Five cores that come together in one product to guarantee excellent and fast therapeutic results.
Our patented thermal control system also allows you to maximize therapeutic results in total safety.
CRYOTHERAPY
High-intensity laser emission allows 4, 6 and 8 wavelengths to be combined and adjusted, and different emission modes to be combined to achieve the best therapeutic effect. By using the different wavelengths in the most suitable combination, it is possible to achieve the perfect mix for a given pathology and a given patient.
The table shows the wavelengths that can be used and the relative characteristics of each.
The CHELT device takes advantage of THEAL Therapy's extensive power range, which extends the application possibilities of phototherapy by combining low-energy laser therapy (LLLT) and high-intensity laser therapy.
In addition to using the different wavelengths in a flexible and customised manner, the operator can vary the emission power, thus treating different pathologies with the most suitable applicators and transferring the energy to the tissues more quickly and effectively.
Choosing the emission mode from the 16 already configured is as easy as pressing a button.
They range from constant CW delivery, to the three pulsed modes, the two customised modes pulsed and superpulsed, the burst trains of high-intensity pulses, the single pulse, and the anti-inflammatory mode.
implemented to generate a rapid analgesic effect
containing the thermal effects on tissue.
implemented to optimise treatment results.
Both handpieces can be used for THEAL-CRIO treatments.
developed according to your needs
Mectronic Advanced Medical Academy
Installed worldwide
MODEL
|
CHELT F
QR 30
|
CHELT F
QS 30
|
CHELT F
EX 50
|
CHELT F
NX 90
|
POWER
|
30 W | 30 W | 50 W | 90 W |
WAVELENGTH
|
650 nm
810 nm
980 nm
1064 nm
|
650 nm
810 nm
905 nm
1064 nm
|
650 nm
780 nm
810 nm
905 nm
980 nm
1064 nm
|
450 nm
650 nm
780 nm
810 nm
905 nm
980 nm
1064 nm
1210 nm
|
SOFTWARE
|
Proprietary Real-Time Operating System MecOS 5.0 |
GUIDING LIGHT
|
650 nm - Fino a 3 mW |
EMISSION
|
• Continuous (CW)
• Single Pulse
• Puls1
• Puls2
• Puls3
• E²C (patented stochastic mode)
• AntInf
• HPM
• Dimmer
• Burst
• Wave creator
|
WORKING MODES
|
Manual |
SPECIAL MODES |
• Joule Mode
• Timer Mode
• Trigger Point Mode
• Effect Finder
• Tissue Target System
• Tissue Thermal Control Mode
|
EFFECTS MODE
|
Protocols for maximising the main effects • Anti-inflammatory • Decontracting • Anti-edema • Analgesic |
MODE
AUTOMATIC SCANX |
• Manual • Automatic (ScanX) |
PROTOCOLS
|
• Over 150 predefined protocols
• Possibility of creating customised protocols |
CALIBRATION
|
Graphic and acoustic laser emission control system on exit from the handpiece, according to CEI EN 60825-1 |
DISPLAY
|
15.6” Full HD TFT colour touch-screen display |
POWER SUPPLY
|
• 230V - 50Hz
• 110-120V - 60Hz
|
ABSORPTION
|
160VA |
DIMENSIONS
|
400 x 823 x 1398 mm
|
WEIGHT
|
90 kg |
LASER CLASS
|
IV |
BEAM DIVERGENCE
|
25° |
PULSE DURATION
|
1-1000 ms |
CLASSIFICATION IP
|
• Device: IPX0 • Handpiece: IPX0 • Pneumatic foot pedal: IPX4 |
OPERATING
CONDITIONS |
• 10°C ÷ 45°C • 30 ÷ 75% non-condensing humidity • 700 ÷ 1060 hPa |
CONDITIONS OF
TRANSPORT AND STORAGE |
• -10°C ÷ 55°C • 10 ÷ 100% non-condensing humidity • 500 ÷ 1060 hPa |
EMP
|
Maximum permitted emission on the skin 5600W/m² |
EMP
|
Maximum permitted emission on the cornea 9W/m² |
DNRO
|
Nominal Ocular Hazard Distance 13.5m (50W) 18m (90W) |
COMPLIANCE
|
IEC/EN 60601-1; IEC 60601-1-2; IEC 60601-2-22 |
CERTIFICATION
|
CE0051 |
GUIDELINE 93/42
|
IIB Classification |
WARRANTY
|
2 Years |
Have you ever calculated how many patients you see each week for muscle, tendon and ligament and joint problems?
And how many of these could you treat with the CHELT device?