Does your practice require a real leap in quality to meet the increasingly sophisticated needs of your patients?
You have no more excuses, today there is the Ixyon XP: a device that is unequalled in terms of power, number of wavelengths available and emission modes that can be activated.
A true concentrate of unprecedented features that will help you respond promptly and professionally to the most demanding therapeutic challenges, improving performance in terms of speed of recovery, number of pathologies treated and treatment safety.
The operator can save the mode and the combination of emission modes created, achieving an even more flexible and high-performance result.
This is not a simple thermal control, commonly available in laser and cryotherapy treatment devices, but a temperature measurement system that can stop therapy and send an alarm to the operator when a predefined critical threshold is reached.
But this is not the only difference that puts our patented technology at a higher level: the vobulate mode allows the temperature to be kept within predefined thermal thresholds, further improving the quality of therapy results.
The practical ScanX module allows you to carry out THEAL Therapy treatments in automatic mode, i.e. without operator intervention, while maintaining a high level of safety and guaranteeing the best therapeutic performance.
The module is equipped with vobulated thermal control, which keeps the device within predefined thermal thresholds.
To ensure the professionalism of the treatments you offer your patients, you need high-performance instruments that are simple, lightweight and comfortable to use.
In other words, ergonomic instruments designed with your hands and technical skills in mind.
At the heart of the machine interaction system is the ergonomic and ultra-compact Light Blade XP handpiece, designed to reduce operator fatigue and improve efficiency.
We have designed the Finger Switch, that allows you to activate the laser emission easily and effortlessly, while the polychromatic LED system integrated in the instrument keeps you updated in real time on the progress of the therapy.
We have designed ten different applicators that you can attach to the Light Blade handpiece according to your chosen therapy and the characteristics of your patient:
compact
large
Why choose Ixyon XP from Mectronic?
Because it is a Made in Italy device appreciated worldwide.
An Italian product
that has conquered the world
We help you win new customers
with marketing tools designed for you
Practical, intuitive, functional and constantly updated training courses
We are reliably and continuously present at every stage of product life
Collaborations with academic and research centres, sports clubs and specialists
Over 700 satisfied customers worldwide
DEVICE | IXYON XP F, IXYON XP F50 |
SOFTWARE
|
Mectronic’s own MecOS 5.0 OMNIA Real-Time Operating System |
WAVELENGTH
|
• 650 nm
• 780 nm
• 810 nm
• 905 nm
• 980 nm
• 1064 nm
|
GUIDE LIGHT
|
650 nm - Up to 3 mW |
LASER POWER
|
Up to 100 W |
EMISSION
|
• Continuous (CW) • Pulsed • Super-pulsed • E²C (patented stochastic mode) • AntInf • HPM • Dimmer • PBM • THP • Sinusoidal • Trapezoidal |
OPERATION MODE
|
• Time |
SPECIAL MODES |
• Effect Finder |
EFFECT MODE
|
5 specific emission modes to maximise the 5 main effects of THEAL therapy: • Bio-stimulant • Analgesic • Anti-inflammatory • Anti-edema • Decontracting |
PATHOLOGIES
|
Over 150 pathologies with interactive illustrations and protocols sub-divided by phase
|
CALIBRATION
|
Graphic and acoustic control system for laser emission at handpiece exit in accordance with norm. CEI EN 60825-1 |
DISPLAY
|
Colour IPS HD 10,1” Touch-screen |
SUPPLY
|
100÷240V 50÷60Hz |
ABSORPTION
|
160VA |
DIMENSION
|
• Without cart: 300 x 450 x 250 mm • With cart: 300 x 450 x 1070 mm |
WEIGHT
|
• Without cart: 7 kg • With cart: 22 kg |
LASER CLASS
|
IV |
BEAM DIVERGENCE
|
25° |
PULSE WIDTH
|
1-1000 ms |
IP CLASSIFICATION
|
• IPX0 device • IPX0 handpiece • IPX4 pneumatic footswitch |
TERMS
OPERATING |
• 0°C ÷ 30°C • 30 ÷ 75% humidity non-condensing • 700 ÷ 1060 hPa |
TERMS TRANSPORTATION AND STORAGE
|
• -10°C ÷ 55°C • 10 ÷ 100% humidity non-condensing • 500 ÷ 1060 hPa |
EMP
|
Maximal emission permit on skin 5600W/m² |
EMP
|
Maximal emission permit on cornea 9W/m² |
DNRO
|
Nominal Distance of Ocular Risk 10m |
CONFORMITY
|
EN 60601-1; EN 60601-1-2; EN 60601-2-22 |
CERTIFICATION
|
CE0051 |
DIRECTIVE 93/42
|
IIB Classification |
WARRANTY
|
2 years |
"The possibility of not achieving therapeutic results with this cutting-edge laser technology is really very low. One case could be that of administering an incorrect therapeutic dose. The new generation laser device Ixyon XP completely removes this risk. The calculation of the therapeutic dose is in fact entrusted to an innovative software that guides the therapist in the input of pathological and morphological variables. With this technological solution, therapeutic results are totally guaranteed!" |
“ Medical Surgeon and FMSI Adjunct Physician”
Set yourself apart from the competition, invest in the
well-being of your patients
How many patients come to you every week?
How many of them could you treat effectively thanks to Ixyon XP?